CBKMR - STATHANE 6502H, COMPONENT 1

Product Identification

Product ID:STATHANE 6502H, COMPONENT 1
MSDS Date:08/02/1995
FSC:6850
NIIN:00N069504
MSDS Number: CBKMR

Responsible Party
EXPANDED RUBBER AND PLASTIC CORP
14000 SOUTH WESTERN AVE
GARDENA, CA 90249
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 213-324-6692

Cage: 25598

Contractor
EXPANDED RUBBER AND PLASTIC CORP
GARDENA, CA 90249-3008 US

Telephone: 310-321-4260

Cage: 25598

Ingredients

POLYMETHYLENEPOLYPHENYL ISOCYANATE; (POLYMERIC

CAS: 9016-87-9

RTECS: TR0350000

Fraction By Weight: <90%

OSHA PEL N/K

ACGIH TLV: 0.02 PPM (MFR)


2-PROPANOL, 1,3-DICHLORO-; (CHLORINATED PHOSPHATES)

CAS: 13674-87-8

RTECS: UB1473000

Fraction By Weight: >10%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:VAPOR INHALATION MAY CAUSE SEVERE
IRRITATION OF RESPIRATORY TRACT. LIQUID CONTACT MAY CAUSE SKIN AND
EYE BURNS. IRRITATION OF RESPIRATORY TRACT, CHEST DISCOMFORT,
SHORTNESS OF BREATH, SENSITIVE PEOPLE RESPOND TO CONCENTRATIONS
BELOW TLV WITH ASTHMA ATTACKS. ABOVE TLV WITH BRONCHITIS, BRONCHIAL
SPASMS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:AND PULMONARY EDEMA MAY OCCUR. THESE
SYMPTOMS ARE USUALLY REVERSIBLE.
Medical Cond Aggravated by Exposure:RESPIRATORY AND BRONCHIAL
CONDITIONS. SKIN SENSITIVITY.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. GET MEDICAL
ATTENTION. SKIN: WASH THOROUGHLY WITH SOAP AND WATER. INHALATION:
MOVE OUT TO FRESH AIR. GIVE OXYGEN IF NECESSARY. GET MEDICAL
ATTENTION IF NECESSARY. INGESTION: DO NOT INDUCE VOMITING. GIVE
WATER OR MILK. GET MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:390F,199C
Extinguishing Media:DRY CHEMICAL, CO*2 HIGH EXPANSION CHEMICAL FOAM.
WATER SPRAY FOR LARGE FIRES.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . MDI VAPORS AND OTHER HIGHLY TOXIC GASES MAY BE
GENERATED BY THERMAL DECOMP OR COMBUSTION.
Unusual Fire/Explosion Hazard:AT OVER 400 F MDI CAN POLYMERIZE AND
CREATE PRESSURE IN CLOSED CONTAINERS. EXPLOSIVE RUPTURE IS
POSSIBLE. USE COLD WATER TO COOL FIRE EXPOSED CONTAINER.

Accidental Release

Spill Release Procedures:ABSORB MATL W/SAWDUST/SWEEPING COMPOUND,
SHOVEL INTO OPEN CNTNRS. NEUTRALIZE W/MIX OF WATER (90%),
CONCENTRATED AMMONIA (3-8%) & DETERGENT (2%). ADD ABOUT 10 PARTS OF
NEUTRALIZER PER ONE PART OF SPILL . LEAVE CNTNR OPEN FOR 48 HRS IN
WELL-VENT AREA.
Neutralizing Agent:WATER (90%), CONCENTRATED AMMONIA (3-8%) & DETERGENT
(2%)

Handling

Handling and Storage Precautions:AVOID MOISTURE CONTAM. DO NOT SEAL
CONTAINERS W/CONTAMD MATERIAL. GAS GENERATION & PRESSURE BUILD UP
COULD RUPTURE CONTAINER. STORE BETWEEN 64-86F.
Other Precautions:MATERIAL CAN PRODUCE ASTHMATIC SENSITIZATION FROM
SINGLE INHALATION. EXPOSURE TO VAPOR FROM HOT MIX CAN BE EXTREMELY
DANGEROUS.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SOL IN H*2O: REACTS SLOWLY WITH WATER GENERATING CO*2. CNDTNS (STAB):
SEAL CONTAINERS WITH CONTAMINATED MATERIAL.

Chemical Properties

Boiling Pt:B.P. Text:406F,208C
Vapor Pres:10-5 @ 77F
Vapor Density:8.5
Spec Gravity:1.24 (H*2O=1)
Solubility in Water:SUPDAT
Appearance and Odor:BROWN, LOW VISCOSITY LIQUID. MUSTY ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
BASIC COMPOUNDS, CAUSTIC SODA, TERTIARY AMINES, WATER.
Stability Condition to Avoid:PRLNG HEATING ABOVE 160F OR STOR BELOW
75F. MOISTURE CONTAM/OTHER MATLS THAT REACT W/DIISOCYANATES. DO NOT
(SUPDAT)
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Conditions to Avoid Polymerization:MOISTURE CONTAMINATION OR OTHER
MATERIALS THAT REACT WITH DIISOCYANATES. DO NOT SEAL CONTAINERS
W/CONTAMINATED MATERIAL.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.